Overhead hoods are generally used for the capturing of light fumes and solvent emissions releasing the workstation
Built-in hoods are generally used for needs of filtration when the workstation is encumberred and when the flow to be filtered is heavier than the air, so naturally attracted downwards
Overhead hoods HI9P
Overhead hood HI9P
The workstation is completely clear, to be suspended thanks to 4 chains
Visor in translucent PVC, 720 x 640mm
Can be used in ductless application (active carbon filter or dust filter) or for an evacuation outside
Application : above a bath of solvents, or solder fume system...
Technical characteristics
Variable flow
Capacity
L x W x H mm
Weight
Integrated lighting
Power supply
Maintenance
rear exit evacuation
50 to 450 m3/h
320 W 720 x 640 x 290 mm(total dimensions)
12 Kg
Yes
230 V / 50 Hz
Periodic change of the filter
Yes Ø 125 mm
Hood HI9P
Built-in hoods HI2P
Built-in hood HI2P : work on the hood
Building in of the hood in a bench
Adapted for filtration where an aspiration from the bottom is needed (for example heavy substances, solvents, etc.) The workstation is completely clear
Can be used in ductless application (active carbon filter or dust filter) or for an evacuation outside
Application : solder fume extraction, heavy solvents extraction, ....
Technical characteristics
Variable flow
Capacity
L x W x H mm
Weight
Integrated lighting
Power supply
Maintenance
rear exit evacuation
50 to 450 m3/h
270 W 420 x 350 x 130 mm
9 Kg
Yes
230 V / 50 Hz